Ambulatory Blood Pressure Monitoring Testing Standard Based on Ministerial Decree 260 of 2024

Ambulatory Blood Pressure Monitoring Testing Standard Based on Ministerial Decree 260 of 2024

Ambulatory Blood Pressure Monitoring (ABPM) uses communication technologies such as Bluetooth or (Short Range Devices) SRD that operate within a specific frequency spectrum. This technology must meet the main requirements through a standard testing process to ensure its quality, security, and compliance with applicable regulations.

This standard ambulatory blood pressure monitoring testing process is stated in the Ministerial Decree of the Ministry of Communication and Digital No. 260 which regulates various technical aspects, ranging from radio frequency, and transmit power, to testing methods.

Bluetooth or SRD technology, which is widely used ambulatory blood pressure monitoring devices must comply with this standard to be used legally in Indonesia.

New Ambulatory Blood Pressure Monitoring Technology

Ambulatory Blood Pressure Monitoring Testing Standard Based on Ministerial Decree 260 of 2024 2

Ministerial Decree of the Ministry of Communication and Digital No. 260 of 2024 sets technical standards that must be met by ambulatory blood pressure monitoring devices to be used legally in Indonesia.

This regulation covers radio frequency requirements, maximum transmit power, and testing for wild emissions (spurious emissions).

The following are the standard specifications for Bluetooth:

Radio Frequency BandsMaximum Transmit Power
Spurious Emission Transmitter

Test Method
2400-2483,5 MHz≤ 20dBm EIRPFCC 15.247 and/or 15.209FCC 15.247 and ANSI C63.10
EN 300 440EN 300 440
EN 300 328EN 300 328

The following are the standard specifications for Medical and Biological telemetry:

Radio Frequency BandField strength / RF output powerTransmitter Spurious EmissionTesting MethodOther Condition
9 – 315 kHz≤ 23 dBmA/m at 10 meters distanceEN 302 195EN 302 195Duty cycle ≤ 10%
40.5 – 41 MHz≤ 0.01 mW ERPEN 300 220-1EN 300 220
216 – 217 MHz≤ 112 dBV/m at 10 meters distanceEN 300 422EN 300 422

Ambulatory Blood Pressure Monitoring Testing Standards

Ambulatory Blood Pressure Monitoring Testing Standard Based on Ministerial Decree 260 of 2024 3

Ministerial Decree of the Ministry of Communication and Digital No. 260 of 2024 refers to international standards-based test methods such as FCC, EN, and ANSI. Here are some of the main testing methods:

  • Transmit power testing (RF output power): Ensure the device does not exceed the maximum transmit power limit according to its frequency band.
  • Spurious emission testing: Tests stray frequency emissions outside the working band to prevent interference with other devices.

Electromagnetic Compatibility (EMC) Testing: Assesses the device’s compatibility with the surrounding electromagnetic environment to avoid interference.

Additional technical requirements

Apart from testing transmittance and emissions, the Ministerial Decree of the Ministry of Communication and Digital No. 260 of 2024 also regulates several other technical requirements, including:

  • Electrical safety: The device must comply with the electrical safety standards set out in SNI IEC 60950-1:2016; SNI IEC 62368-1:2014; SNI 04-6253; IEC 62368-1; IEC 60950-1; IEC 60065; or relevant SNI or IEC standards, for SRD other than audio, video and information and communication technology (ICT).
  • Non-Ionizing Radiation: Controls device radiation levels to keep them safe for users and the environment.

Ambulatory Blood Pressure Monitoring Certification Process in Indonesia

Ambulatory Blood Pressure Monitoring Testing Standard Based on Ministerial Decree 260 of 2024 4

For ambulatory blood pressure monitoring devices to be used legally in Indonesia, certification from DJID is required. Here are the steps to get it:

Pre-testing the device

Before official testing, the device must be pre-tested first using measuring equipment such as a spectrum analyzer.

This helps ensure devices meet technical standards before being tested in authorized laboratories.

Testing at an official laboratory

After passing the pre-testing stage, the device will be sent to a designated official laboratory to undergo testing by the standards stipulated in the Ministerial Decree of the Ministry of Communication and Digital No. 260 of 2024.

Issuance of certificates

After the device passes testing, DJID will issue an official certificate. This certificate is required to market the device legally in Indonesia.

Tips to ensure standards compliance

  • Learn the latest regulations: Make sure you understand every detail of the Ministerial Decree of the Ministry of Communication and Digital No. 260 of 2024, including technical requirements and test methods.
  • Perform pre-testing: Before official testing, perform pre-testing to ensure the device meets standards. If you don’t have a measuring instrument, use the DJID certification service which provides pre-testing services.
  • Consult an expert: If this is your first time seeking certification, consider using experienced DJID certification services.

Popular Post

5 Best Wireless Keyboard

Electronics

5 Best Wireless Keyboard

Best Wireless Keyboard – In today’s market, you’re no longer stuck with clunky wires! From lightning-fast gaming keyboards with pro-level ...

What is Radar

Regulations

What is Radar? How it Works and How is Testing Standard

We often see radar in the airport or even in the sci-fi or action movie. Especially for the movie, many ...

Adobe's Ink and Slide

Electronics

Introducing Adobe’s Ink and Slide, a useful Touch Pen

Adobe’s Ink, – narmadi.com. The development of touchscreen technology has forced manufacturer to manufacture their device under the full screen ...

Leave a Comment