The Infocomm Media Development Authority (IMDA) of Singapore has taken an important step by launching the SS 715:2025 Energy Efficiency Standards. This step was taken to move towards a sustainable digital infrastructure.
In addition to the Energy Efficiency Standard, Singapore has also set minimum performance levels for data center IT equipment, including servers, storage, and network devices. This is in line with international standards such as US Energy Star and EU Ecodesign, which ensure that data centers operate efficiently in accordance with global regulations.
Energy Efficiency Standard Requirements
The SS 715:2025 Energy Efficiency Standard is designed based on Singapore’s Green Data Center Action Plan. Its technical requirements are clearly outlined in the operational guidelines. This standard discusses best practices in implementation and management.
Some of the provisions covered are minimum performance levels, operational practices, and operating temperatures. For minimum performance levels, IT equipment must meet energy efficiency limits that are in line with Energy Star and Ecodesign.
Operational practices must encourage the replacement of old devices with newer, more efficient units. In addition, underutilized equipment needs to be upgraded more regularly to increase its utilization.
For operational temperatures, equipment must be able to operate safely up to 35°C. This is to reduce the need for cooling. In addition, the right temperature will result in additional energy savings of around 2–5% for every increase in temperature.
Government Support for New Standards Compliance
IMDA assists in adapting to these Energy Efficiency Standards. There will be an Energy Efficiency Assistance Program to help operators upgrade their equipment in accordance with the new requirements. These standards also complement the Tropical Data Center Standard SS 697:2023, which already supports operations in high temperatures in tropical environments.
Furthermore, this initiative provides clarity on market access for IT equipment manufacturers and suppliers. In line with global frameworks, Singapore is striving to comply with and facilitate a smoother certification process.
What is the Importance of This New Standard?
The Energy Efficiency Standard certainly has an impact on operators and stakeholders in establishing regulatory bases for IT equipment efficiency in Singapore. In addition, this standard is also in line with local compliance with global standards, supporting international competitiveness.
Furthermore, it will encourage sustainable operational practices, reducing costs and environmental impact. Most importantly, data centers need to evaluate their current equipment based on the SS 715:2025 standard. This involves considering updates and revising internal monitoring processes to remain compliant with regulations.
How Data Center Operators Can Prepare
A new standard often brings one big question: where do we start? The answer is simple. Start with what you already have. Here are some practical steps based on the provisions of SS 715:2025.
1. Make an Inventory of Your IT Equipment
List all servers, storage, and network devices in your data center. Write down the model, the age, and how much each unit is being used. This list is the basis for every next step.
Without an inventory, it is hard to know which equipment already meets the minimum performance levels and which does not.
2. Compare With the Minimum Performance Levels
The standard requires IT equipment to meet energy efficiency limits in line with Energy Star and Ecodesign. Use this as a reference when you review your inventory. Mark the units that may need attention.
3. Look at Old and Underutilized Equipment
Operational practices in this standard encourage the replacement of old devices with newer, more efficient units. Underutilized equipment also needs to be upgraded more regularly to increase its utilization.
So, from your inventory, pick the old units and the ones that are rarely used. These are usually the first candidates for an upgrade.
4. Check the Operating Temperature
Equipment must be able to operate safely up to 35°C. Ask your suppliers whether your current equipment supports this. If you operate in a tropical environment, the Tropical Data Center Standard SS 697:2023 is also worth reading.
5. Update Your Internal Monitoring
As mentioned above, data centers need to evaluate their current equipment and revise internal monitoring processes. Make sure your team can track energy use and equipment utilization regularly, not only once a year.
6. Find Out About the Assistance Program
IMDA provides an Energy Efficiency Assistance Program to help operators upgrade their equipment. It is worth finding out whether your data center can take part.
What About Manufacturers and Suppliers?
For IT equipment manufacturers and suppliers, this standard gives clarity on market access in Singapore. If your products already follow Energy Star or Ecodesign, you have a good starting point. Still, review your product documents, so that you can show how each product meets the requirements.
Frequently Asked Questions
Who launched the SS 715:2025 standard?
The Infocomm Media Development Authority (IMDA) of Singapore.
What is the standard based on?
It is designed based on Singapore’s Green Data Center Action Plan.
Why does the operating temperature matter?
Operating safely up to 35°C reduces the need for cooling. The right temperature results in additional energy savings of around 2–5% for every increase in temperature.
Which equipment is covered?
Data center IT equipment, including servers, storage, and network devices.